Are you ready for contact us ?

Contact us

#1 Perimeter Sealing Guide for Below-Slab Vapor Barrier Installation

This helpful guide to under-slab vapor barrier installation will consider the most common slab designs, their terminating edges and how to seal at/to the perimeter of your foundation in accordance with your designer's specifications and ASTM E1643. How to Seal the Vapor Barrier at Temporary Concrete Forms: Will You Miss Them When …

10 and 15 Mil Underslab Vapor Barrier & Vapor …

PERMINATOR underslab vapor barrier is a new generation of polyolefin-based resin/chemical technology. PERMINATOR provides the vapor barrier industry with a highly effective, economical choice for helping to …

Concrete Vapor Retarders: Everything You Need …

One contractor is suggesting that the dirt/mud under my house be graded so that the rainwater flows quickly through the crawl space, a vapor barrier (6 ml plastic) be placed on top of the graded …

Should You Put Rigid Insulation Under Concrete …

Do You Need a Vapor Barrier Under a Concrete Slab? A vapor barrier is an essential part of a good slab foundation. Since water from the soil soaks into the rigid insulation over time, it's necessary to put a barrier between …

Concrete Vapor Barriers for Under Slabs

Vapor barriers beneath a concrete slab stop vapor transmission and related problems. Learn why a quality vapor barrier is better than just using a sheet of plastic under your concrete.

Concrete Foundations: Under-Slab Vapor Barriers Done Right

A properly selected and installed polyethylene vapor barrier between the slab and the soil effectively keeps ground moisture away from the concrete to mitigate …

Stego® Wrap Vapor Barrier (15-mil)

Stego's groundbreaking 15 Mil Vapor Barrier is the flagship product of Stego Industries and is manufactured with a proprietary blend of prime resins and additives. ... ASTM E1745: Standard Specification for Water Vapor Retarders Used in Contact with Soil or Granular Fill Under Concrete Slabs ; ASTM F1249: ...

Vapor Barriers and Concrete: Everything You Want To Know …

You should use a 6-mil or 10-mil (0.15–0.25 mm) polyethylene sheet as a vapor barrier under a concrete slab. These thicknesses are durable and effective at preventing moisture problems. However, 10-mil (0.15 – 0.25 mm) is the industry standard. You will only use a thinner sheet if you're putting down a vapor barrier over an existing ...

Vapor Barriers Under Concrete Slabs Guidance for …

Vapor Barriers Under Concrete Slabs – Guidance for Selection and Location 2020 Instructor: Brian M. McCaffrey, P.E. PDH Online | PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone: 703-988-0088 An Approved Continuing Education Provider

Radiant Floor Heating Concrete Slab Insulation Guide

Tape it Up: Employ white adhesive insulation tape for sealing rolls at the seams, a step ensuring the vapor barrier's integrity. Add Sand: Spread a 1-inch layer of sand atop the insulation. This assists in draining water and can potentially expedite the concrete curing process. ... Once installed and shielded by concrete, under slab ...

Vapor barriers under concrete slabs

quire the use of a vapor barrier under concrete slabs. Even though the use of a vapor barrier might be com-mon, the specified location of the va-por barrier varies. Some specifiers re-quire a sand layer or a crushed base over the vapor barrier. Others insist that the vapor barrier be placed direct-ly under the slab. Specifiers must care-

Viper II Under-Slab Vapor Barrier

Viper II below-slab vapor barrier is the first line of defense against damaging water vapor and soil gas threats existing below the concrete slab. Viper II products are multi-layer (co-extruded), polyolefin under-slab vapor barriers/retarders.

Do You Need To Put Rigid Insulation Under Concrete Slab?

A vapor barrier under a concrete slab is essential as it enhances the foundation of the concrete slab. It will prevent moisture from penetrating the concrete slab as water tends to soak into the rigid insulation over time.

Vapor Barriers Under Concrete Slabs | Stego Technical

Concrete Construction, April, 1992. Vapor barriers are used to minimize moisture inflow through concrete in contact with water or water vapor. They can protect floor coverings or electronic equipment. They can also minimize the infiltration of radon. Vapor barriers can also influence finishing time, cracking and strength of the concrete slab."

BSD-106: Understanding Vapor Barriers | buildingscience

The function of a vapor barrier is to retard the migration of water vapor. ... building assemblies all remained below the equilibrium moisture content of the materials as specified in ASHRAE 160 P under this evaluation approach. ... Concrete slab floors in ground contact are required to have a Class I vapor retarder below the slab in direct ...

Optimal Vapor Barrier for Under Concrete

Extends slab life: A vapor barrier helps maintain a drier slab, potentially extending its lifespan. What is the code for vapor barrier under a concrete slab? Building codes may vary, but ASTM E1745 and ASTM D4397 are common standards for vapor barriers under concrete, guiding material and installation requirements.

The 5-Step Guide to Installing a Residential Below-Slab Vapor Barrier

The below-slab vapor barrier certainly falls into this category. Notice, I say "vapor barrier" not mere plastic or poly – there's a difference. This is the highly engineered plastic extrusion that should go directly beneath your concrete slab. ... Installation, and Inspection of Water Vapor Retarders Used in Contact with Earth or Granular ...

Do I Need a Vapor Barrier Under Concrete Slab?

5 Reasons Your Building Needs a Below-Slab Vapor Barrier

Toxic Gases and Chemicals Are Also Barred: Moisture is not the only enemy that needs to be combatted against; toxic and harmful chemicals can also seep into the building from the ground.Ultimately, there are many naturally occurring gases, such as radon, methane, gasoline, solvents, oils, and hydrocarbons that can easily migrate …

Under Slab Insulation: The Only Guide You'll Need — Rmax

Here are a few more incentives to insulate with rigid under concrete slabs: Protection. If you've ever noticed a crack in the sidewalk, you've seen how susceptible concrete can be to shifting inherently caused by the freeze-thaw cycle. ... Roll out a vapor barrier, such as polyethylene plastic. Lay your insulation boards in a ...

Proper Placement of Vapor Barriers

We would like to resolve the question of proper placement of vapor barriers under concrete slabs on grade. We have a system that has worked well for us in the past. In nonproblem areas we have traditionally used 6-mil polyethylene film directly under concrete slabs and over a granular fill on the subgrade. This produces a very …

Creating a Moisture & Vapor Barrier Under Concrete Slab

The most commonly used vapor barrier under concrete slabs is polyethylene (poly) plastic sheeting with a thickness of 10 mil or 15 mil. All Americover Vapor Barriers are composed of polyolefin resins and offered in 10 mil, 15 mil, and 20 mil. These are high-performance materials designed to stop moisture migration and prevent gases or ...

Vapor barriers under concrete slabs

%PDF-1.0 9 0 obj /Length 10 0 R /Filter [ /ASCII85Decode /LZWDecode ] >> stream J.)V!+fKqZ+9mdX"K4]oE$-!R+i4>DS/O7&^u1t"R)Us*NlFQYZ*.l,Dm@)VJ&@c cNkDJA)h")SdI=l ...

When and Where to Install a Below-Slab Vapor …

A below-slab vapor barrier has a permeance rating of less than 0.01 perms to provide exceptional protection against water vapor diffusion. Making sure that vapor barrier meets ASTM E1745 Class A is …

Under Slab Vapor Retarders/Barriers (White Paper)

The use of under slab vapor retarders/barriers has long been regarded as an effective, economical way to control moisture migration through concrete. ... Installation, and Inspection of Water Vapor Retarders Used in Contact with Earth or Granular Fill under Concrete Slabs; Water Vapor Permeance requirements per ASTM E1745-11 call for a …

The Best Moisture Barrier for Protecting Concrete Slabs …

Properly protect your investment from the ground up with a high-performance under-slab vapor barrier system. ... (Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs) is a testing standard used for determining a product's performance. ASTM E 1745 classifies …

Vapor Barriers for Existing Concrete Slabs

Trapped moisture causes toppings to delaminate from the slab. Block water vapor emissions by applying a vapor barrier to the concrete before applying an overlay.

Vapor Barriers under Concrete Slabs -How to Select …

Vapor Barriers under Concrete Slabs - How to Select and Locate Course No: T01-001 Credit: 1 PDH Brian McCaffrey, P.E. Continuing Education and Development, Inc. P: (877) 322-5800 info@cedengineering . VAPOR BARRIERS UNDER CONCRETE SLABS – HOW TO SELECT AND LOCATE Introduction

Vapor Barriers for Existing Concrete Slabs

Slabs that lack under-slab vapor barriers will nearly always have some water vapor emission from water below the slab, and newer slabs, even with vapor barriers, will need time to dry out. Overlay manufacturers typically recommend a moisture vapor emissions rate (MVER) of 3 pounds per 1000 square feet in 24 hours (see Reducing Bond Failures ...

How To Install A Vapor Barrier

Cut another piece of vapor barrier material large enough to cover the damaged area by a minimum of 6 inches on all sides. Tape all the seams to adhere the repair piece to the existing vapor barrier. Those are the basic steps on how to install a vapor barrier under a concrete floor or slab. Installing the vapor barrier is really quite easy as ...

Where to Place Under-Slab Insulation? Above or Below the Vapor Barrier

Under-Slab Insulation Below the Vapor Barrier 🡻 On most projects where insulation meets the under-slab vapor barrier, we have found that the project teams elect to install their insulation first and to lay the vapor barrier over top. Various industry leaders have commented on the advantage of placing the vapor barrier directly beneath the slab.

What is a Vapour Barrier Under A Concrete Slab

So yes, a vapour barrier is required under a concrete slab for a Class 1 building (a dwelling) and for Class 10 (eg a garage) where the slab is continuous with the dwelling. In New South Wales, Clause 3.2.2.6 of the National Construction Code requires the damp-proofing membrane to be 0.2mm polyethylene HIGH impact resistance and …

Specifying Under-Slab Vapor Barriers

W. R. MEADOWS, the originator of under-slab vapor barrier protection, is concerned that confusing information is being provided to you, the specifier. If you design it, you own it, so you need to trust the companies you're dealing with.

Vapor Barriers and Concrete: Everything You Want To Know

You need a vapor barrier under your concrete slab to protect it from moisture damage. This application can be the difference between a durable, long …

Concrete Slab Insulation Amount, Placement, & Vapor Barrier …

Sub Slab Insulation Amount, Location, & Vapor Barrier Placement for Heated Slabs. Accompanying text is reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss.. Our page top photograph shows a horrible radiant floor slab insulation scheme installed by a Minnesota contractor - this radiant floor system …

Vapor Barriers under Concrete Floor Slabs: Friend or Foe?

Vapor Barriers under Concrete Floor Slabs: Friend or Foe? by Steve Ragan, Director, Research and Technical Services The answer to this controversial question, from both angles, is a qualified "yes." Vapor barriers have been associated with certain concrete slab-on-grade problems including curling and cracking. But they have also proven to ...

What is the Best Vapor Barrier to Use Under …

In the 2021 edition of the International Residential Code (IRC), the guidelines were revised to recommend a minimum 10 mil vapor barrier for use under concrete slabs in residential buildings instead of a 6 mil.. …

Are Vapor Barriers Required Under Concrete Floors?

Is a Vapor Barrier Required Under a Concrete Slab? Yes, Section R506.2.3 of the IRC specifies that a 6-mil polyethylene or other approved vapor retarder with joists lapped not less that 6 inches shall be placed between the concrete floor slab and the base course or prepared subgrade.